Extron Electronics, USA1230 South Lewis StreetAnaheim, CA 92805USA714.491.1500 Fax 714.491.1517Extron Electronics, EuropeBeeldschermweg 6C3821 AH Ame
IPL M PDP-ES • Installation and OperationIPL M PDP-ES • Installation and OperationInstallation and Operation, cont’d2-7Resetting the unitThere are fiv
IPL M PDP-ES • Installation and OperationInstallation and Operation, cont’dIPL M PDP-ES3Chapter ThreeConnection and ConfigurationConnecting the Hardwa
IPL M PDP-ES • Connection and ConfigurationIPL M PDP-ES • Connection and ConfigurationConnection and Configuration3-33. Ensure that your PC is connect
IPL M PDP-ES • Connection and ConfigurationIPL M PDP-ES • Connection and ConfigurationConnection and Configuration, cont’d3-5Enter the desired new IP
IPL M PDP-ES • Connection and ConfigurationIPL M PDP-ES • Connection and ConfigurationConnection and Configuration, cont’d3-7IP address: 192.168.254.2
IPL M PDP-ES • Connection and ConfigurationConnection and Configuration, cont’dIPL M PDP-ES4Chapter FourCommunication and ControlCommunication with th
IPL M PDP-ES • Communication and ControlIPL M PDP-ES • Communication and ControlCommunication and ControlCommunication with the Interface CardThe on-b
IPL M PDP-ES • Communication and ControlCommunication and ControlIPL M PDP-ES • Communication and ControlGateway IP addressThe Gateway IP Address fiel
IPL M PDP-ES • Communication and ControlIPL M PDP-ES • Communication and ControlCommunication and Control, cont’dFigure 4-4 — Web server Passwords scr
IPL M PDP-ES • Communication and ControlIPL M PDP-ES • Communication and ControlCommunication and Control, cont’dnotification indicating the number of
PrecautionsThis symbol is intended to alert the user of importantoperating and maintenance (servicing) instructionsin the literature provided with the
IPL M PDP-ES • Communication and ControlIPL M PDP-ES • Communication and ControlCommunication and Control, cont’dUpdate the firmware as follows:1. Vis
IPL M PDP-ES • Communication and ControlIPL M PDP-ES • Communication and ControlCommunication and Control, cont’dIf you wish to delete all files, clic
IPL M PDP-ES • Communication and ControlIPL M PDP-ES • Communication and ControlCommunication and Control, cont’dControl for Input 3, Input 4, and Inp
IPL M PDP-ES • Communication and ControlIPL M PDP-ES • Communication and ControlCommunication and Control, cont’dEnergy SaveWhen an energy save functi
IPL M PDP-ES • Communication and ControlCommunication and Control, cont’dIPL M PDP-ES • Communication and Controlexample of each command in ASCII (Tel
IPL M PDP-ES • Communication and ControlIPL M PDP-ES • Communication and ControlCommunication and ControlThere is a 7 character limit for full file na
IPL M PDP-ES • Communication and ControlIPL M PDP-ES • Communication and ControlCommunication and Controlcommand contains invalid parameters, it retur
IPL M PDP-ES • Communication and ControlIPL M PDP-ES • Communication and ControlCommunication and Control, cont’d4-25Command ASCII (Telnet) URL
IPL M PDP-ES • Communication and ControlIPL M PDP-ES • Communication and ControlCommunication and Control, cont’d4-274-26Command ASCII (Teln
IPL M PDP-ES • Communication and ControlIPL M PDP-ES • Communication and ControlCommunication and Control, cont’d4-294-28Command ASCII (Telnet)
IPL M PDP-ES • Quick Start GuideQS-1To install and set up the IPL M PDP-ES interface card, followthese steps:Step 1Turn all of the equipment off and d
IPL M PDP-ES • Communication and ControlIPL M PDP-ES • Communication and ControlCommunication and Control, cont’d4-31.4-303. At the < to > promp
IPL M PDP-ES • Communication and ControlCommunication and Control, cont’dIPL M PDP-ESAAppendix ASpecifications, Part Numbers,and AccessoriesSpecificat
IPL M PDP-ES • Specifications, Part Numbers, AccessoriesIPL M PDP-ES • Specifications, Part Numbers, AccessoriesSpecifications, Part Numbers, and Acce
IPL T S Series • Specifications, Part Numbers, and AccessoriesSpecifications, Part Numbers, Accessories, cont’dIPL M PDP-ESBAppendix BGlossaryA-4
IPL M PDP-ES • GlossaryIPL M PDP-ES • GlossaryGlossaryB-3devices you have and your current list of IP addresses. Withthis information, GVC creates a
IPL M PDP-ES • GlossaryIPL M PDP-ES • GlossaryGlossary, cont’dB-5B-4Port number is a preassigned address within a server thatprovides a direct route f
IPL M PDP-ES • GlossaryGlossary, cont’dB-6
IPL M PDP-ES • Quick Start GuideQuick Start Guide — IPL M PDP-ES, cont’diIPL M PDP-ES • Table of ContentsChapter 1 • Introduction ...
iiIPL M PDP-ES • Table of ContentsTable of Contents, cont’dIPL M PDP-ES1Chapter OneIntroductionAbout this ManualAbout the IPL M PDP-ES Interface CardF
IPL M PDP-ES • IntroductionIntroductionIPL M PDP-ES • Introduction• Email Alerts — Email reminders can be sent to aspecified mailbox automatically whe
IPL M PDP-ES • IntroductionIntroduction, cont’dIPL M PDP-ES2Chapter TwoInstallation and OperationInstallation OverviewInstallation of the IPL M PDP-ES
IPL M PDP-ES • Installation and OperationIPL M PDP-ES • Installation and OperationInstallation and Operation2-3To remove the Pioneer communication ES
IPL M PDP-ES • Installation and OperationIPL M PDP-ES • Installation and OperationInstallation and Operation, cont’d2-5Panel Features and CablingSee f
Comments to this Manuals