Setup Guide68-1289-01 Rev. D11 08MLC 104 Plus SeriesMediaLink™ ControllersFront coverBack cover: checklist and contact information ... 2Front
MLC 104 Plus Series • IntroductionIntroduction, cont’d1-4About Global ConfiguratorGlobal Congurator (GC) is a software application that gives users th
MLC 104 Plus Series • Introduction 1-5Using GC you can congure a single room controller, or create a web-based remote monitoring system for hundreds
MLC 104 Plus Series • IntroductionIntroduction, cont’d1-6To install Global Congurator from an Extron Software Products CD if Autorun is enabled on yo
MLC 104 Plus Series2Chapter TwoHardware SetupFront PanelRight Side PanelLeft Side Panel and Top PanelPower ConnectionLAN ConnectionFront Host Configura
MLC 104 Plus Series • Hardware SetupHardware Setup2-2Front PanelFront panel controls must be congured using the Global Congurator application (descr
MLC 104 Plus Series • Hardware Setup 2-3Right Side PanelConnectors on the unit's right side panel are described below. a Display RS-232 / IR por
MLC 104 Plus Series • Hardware SetupHardware Setup, cont’d2-4Left Side Panel and Top PanelControls on the left side panel and top panel are described
MLC 104 Plus Series • Hardware Setup 2-5Power ConnectionTo connect the external 12 VDC power supply: 1. Strip the ends of the power supply wires as s
MLC 104 Plus Series • Hardware SetupHardware Setup, cont’d2-6LAN Connection (IP Models Only)Connect a straight-through Ethernet cable to the LAN conne
MLC 104 Plus Series • Hardware Setup 2-7Front Panel Host Configuration PortA 2.5 mm mini stereo jack the provides an RS-232 connection for conguration
Precautions This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with
MLC 104 Plus Series • Hardware SetupHardware Setup, cont’d2-8Device ConnectionsThe following illustrations show examples of A/V and control device con
MLC 104 Plus Series • Hardware Setup 2-9Comm Link connectionMLC 104 Plus SeriesRight Side PanelCOMM LINKA B C D E+V OUTGROUNDCMIR INSCPECBASCP communi
MLC 104 Plus Series • Hardware SetupHardware Setup, cont’d2-10
MLC 104 Plus Series3Chapter ThreeSoftware SetupCreating a Global Configurator Project FileConfiguring a New DeviceTesting the GlobalViewer™ Pages
MLC 104 Plus Series • Software SetupSoftware Setup3-2Creating a Global Configurator Project FileAfter you have installed Global Congurator (GC) softwa
MLC 104 Plus Series • Software Setup 3-35. Click the Right Arrow (Subscribe) button. 6. Repeat steps 3 through 5 for each type of device you plan t
MLC 104 Plus Series • Software SetupSoftware Setup, cont’d3-4Step two: create a new projectTo create a new Global Congurator project le: 1. Select
MLC 104 Plus Series • Software Setup 3-55. Click OK. The Add Device dialog box opens.For an MLC 104 Plus (non-IP model)3. Click Cancel. The Add De
MLC 104 Plus Series • Software SetupSoftware Setup, cont’d3-6Step three: add a device and set up its connectionFor IP modelsFor IP models, obtain the
MLC 104 Plus Series • Software Setup 3-76. If the device you are adding is password protected, enter the appropriate Admin and User passwords. The d
MLC 104 Plus Series • Safety and Compliances 安全须知 • 中文这个符号提示用户该设备用户手册中有重要的操作和维护说明。这个符号警告用户该设备机壳内有暴露的危险电压,有触电危险。注意阅读说明书 • 用户使用该设备前必须阅读并理解所有安全和使用说明。保存说
MLC 104 Plus Series • Software SetupSoftware Setup, cont’d3-8For an MLC 104 Plus (non-IP model)1. Select MLC 104 Plus Series from the IP Link Device
MLC 104 Plus Series • Software Setup 3-9Step four: define the location of the new device (IP models only)Global Congurator allows you to keep track of
MLC 104 Plus Series • Software SetupSoftware Setup, cont’d3-10Step five: save the new Global Configurator fileTo save the new GC project le: 1. Click F
MLC 104 Plus Series • Software Setup 3-11Configuring a New DeviceStep six: configure e-mail server (IP models only)Obtain the following from your networ
MLC 104 Plus Series • Software SetupSoftware Setup, cont’d3-12Step seven: configure e-mail messages (IP models only)The Email Manager dialog box is us
MLC 104 Plus Series • Software Setup 3-13Step eight: configure contacts (IP models only)The Contact Manager dialog box is used to enter the name, e-ma
MLC 104 Plus Series • Software SetupSoftware Setup, cont’d3-14Step nine: assign serial device driversThe Serial Conguration tab of Global Congurator
MLC 104 Plus Series • Software Setup 3-15Step ten: assign IR driversThe IR Conguration tab of Global Congurator allows you to assign a device driver
MLC 104 Plus Series • Software SetupSoftware Setup, cont’d3-16Step eleven: configure the front panelThe Front Panel tab provides a graphical representa
MLC 104 Plus Series • Software Setup 3-17Button repeat rateThe repeat rate is how quickly a button will repeat its function if the button is held down
MLC 104 Plus Series • Safety and Compliances
MLC 104 Plus Series • Software SetupSoftware Setup, cont’d3-18Button modesThe Set Button Modes options allow the user to apply three different modes o
MLC 104 Plus Series • Software Setup 3-19Switcher inputThe Switcher Input eld allows you to assign a specic input from an attached MediaLink Switche
MLC 104 Plus Series • Software SetupSoftware Setup, cont’d3-20Button operationsSelected functions in the Button Operations area of the window are move
MLC 104 Plus Series • Software Setup 3-21When you add multiple functions to a front panel button, you may want to insert a time delay between the func
MLC 104 Plus Series • Software SetupSoftware Setup, cont’d3-22The Button Operations User Defined tab allows users to add button functionality that is n
MLC 104 Plus Series • Software Setup 3-23The Button Operations Light Control tab allows users to assign an indicator color to the Press and Release ac
MLC 104 Plus Series • Software SetupSoftware Setup, cont’d3-24Clear, reset, and auto fill captionsUse the Clear button to clear all front panel button
MLC 104 Plus Series • Software Setup 3-25Step twelve: configure associated control modulesA control module is a faceplate with buttons that can be ass
MLC 104 Plus Series • Software SetupSoftware Setup, cont’d3-262. Select an available control module. 3. Click the Add (right arrow, ) button. The
MLC 104 Plus Series • Software Setup 3-27Step thirteen: create a shutdown scheduleGlobal Congurator’s scheduling feature enables you to schedule spec
iMLC 104 Plus Series • Table of Contents i Table of ContentsChapter One • Introduction ...1-1About th
MLC 104 Plus Series • Software SetupSoftware Setup, cont’d3-283. Enter a unique name in the Schedule Action Name eld. 4. Set the desired schedule t
MLC 104 Plus Series • Software Setup 3-29Step fourteen: create a lamp hour notification (IP models only)Global Congurator’s monitoring feature enable
MLC 104 Plus Series • Software SetupSoftware Setup, cont’d3-305. Select a subject port or device. 6. Select Available Options Lamp Usage: Value. 7.
MLC 104 Plus Series • Software Setup 3-31Step fifteen: create a disconnect notification (IP models only)Global Congurator’s monitoring feature enables
MLC 104 Plus Series • Software SetupSoftware Setup, cont’d3-325. Select a subject port or device. 6. Select Available Options Connection Status: Di
MLC 104 Plus Series • Software Setup 3-33Step sixteen: build the Global Configurator fileBefore a Global Congurator (GC) le is active in the GlobalVie
MLC 104 Plus Series • Software SetupSoftware Setup, cont’d3-34Step seventeen: upload the Global Configurator fileWhen the build process completes, the U
MLC 104 Plus Series • Software Setup 3-35Step eighteen: launch GlobalViewer (IP models only)GlobalViewer is a graphical user interface that is genera
MLC 104 Plus Series • Software SetupSoftware Setup, cont’d3-36Testing the GlobalViewer pagesUse the GlobalViewer graphical user interface (IP models o
Extron’s WarrantyExtron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of pu
iiMLC 104 Plus Series • Table of ContentsTable of Contents, cont’d68-1289-01 Rev. D11 08All trademarks mentioned in this manual are the properties of
© 2008 Extron Electronics. All rights reserved.Extron USA - West Headquarters+800.633.9876Inside USA / Canada Only+1.714.491.1500+1.714.491.1517 FAX
MLC 104 Plus Series1Chapter OneIntroductionAbout this ManualThe MLC 104 Plus MediaLink® ControllersAbout Global ConfiguratorGlobal Configurator Online T
MLC 104 Plus Series • IntroductionIntroduction1-2About this ManualThis setup guide describes the • MLC 104 Plus Series MediaLink® Controllers• Globa
MLC 104 Plus Series • Introduction 1-3MLC 104 IP Plus MediaLink Controller BASSLEVELTREBLEMINI POWER AMPLIFIERMPA 122ONOFFLIMITERSTEREODUALMONOExtr