Power Supply Wiring and Grounding
Figure 7 shows how to wire and ground the connector.
CAUTION: Failure to follow these instructions may result in minor injury. The
two power cord wires must be kept separate while the power supply is plugged in.
Disconnect the power before wiring.
ATTENTION:
Power supply voltage polarity is critical. Incorrect voltage polarity can damage the
power supply and the transmitter or receiver. Identify the power cord negative lead
by the ridges on the side of the cord.
To verify the polarity before connection, plug in the power supply with no load and
check the output with a voltmeter.
The length of the exposed (stripped) copper wires is important. The ideal length is
3/16 inches (5 mm). Longer bare wires can short together. Shorter wires are not as
secure in the connector and could be pulled out.
Extron twisted pair products can be adversely affected by electrostatic discharge (ESD) if
they are not grounded correctly. To prevent malfunctions or product damage, an installer
can correctly ground an Extron twisted pair product by following the diagram in figure 7.
Ground the power port by inserting one end of the grounding wire to the negative or ground
pin on the power input connector.
Power Supply
Output Cord
SECTION A–A
Ridges
Smooth
AA
Tie
Wrap
Rear
Panel
Ridges
Earth
Gr
ound
3/16"
(5 mm)
Max.
POWER
12V
0.5A MAX
Figure 7. Power Connector Wiring and Grounding
NOTE: Do not tin the power supply leads before installing in the captive screw
connector. Tinned wires are not as secure in the connectors and could be pulled out of
the connector.