Receiver Jumpering
By default, the receiver is unidirectional, configured to send serial data from the transmitter
to the receiver, only. If the system has only one receiver, this jumper can be repositioned to
enable bidirectional communication as follows:
1. If applicable, disconnect all cables, remove the receiver from its installation location, and
remove any mounting brackets installed.
2. Remove the two screws from either side of the receiver (four screws total) and lift the
top cover off of the receiver (see figure 2 below).
3. Locate jumper JMP1 on the serial data (top) board and shift the jumper to bridge the
jumper block (see figure 2 below).
4. Place the top cover back into place.
5. Reinstall the four screws removed in step 2. If any mounting brackets were removed in
step 1, put them back into position as you reinstall the screws.
6. If applicable, reinstall the receiver and reconnect all cables.
INPUT
BUFFERED
OUTPUT
OUTPUT
POWER
12V
.5A MAX
MT P R L 1 5HD RS
ON
1 2 3 4 5 6
H SYNC +
V SYNC +
C SYNC
SOG
VIDEO
END UNIT
RS-232
Tx
Rx
Jumper bloc
k JMP1
inside box.
JMP1
JMP2
JMP3
Unjumpered for
Unidirectional
Jumpered for
Bidirectional
Remove 4 screws,
lift top straight up.
Figure 2. Opening the Receiver and Setting the Directional Jumpers