Extron electronics 14400 Setup Guide Page 9

  • Download
  • Add to my manuals
  • Print
  • Page
    / 19
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 8
10 FOX Matrix 320x and FOX Matrix 14400 • Installation 11FOX Matrix 320x and FOX Matrix 14400 • Installation
F
Power connectors — Plug the switcher into two grounded AC
sources.
NOTE: For reliability, connect the Redundant power cord to
either an uninterruptible power source or to a power source that
is completely independent from the primary power source.
G
Primary and Redundant power supply LEDs
Green — Indicates that the associated power supply is operating
within normal tolerances.
Red — Indicates that the associated power supply is operating
outside the normal tolerances or has failed (see Removing and
Installing a Power Supply Module on page 25).
Fiber optic I/O board LED indications
On the ber optic I/O boards, the input and output LEDs on the
transceivers provide useful indications of the status of the lasers and the
reclocking function (see the table below).
OUT
Definition
Output LED
indication
Input LED
indication
Definition
Reclocked at 4.25 Gbps
On On
Reclocked at 4.25 Gbps
Not reclocked, laser off,
or no signal
Off Off
Not reclocked or no
signal
Non-4G signal present or
not reclocked
Fast blink Fast blink
Non-4G signal present or
not reclocked
Front Panel
FOX MATRIX 320x
FIBER OPTIC DIGITAL MATRIX SWITCHER
POWER SUPPLY
PRIMARY 1
REDUNDANT 1
PRIMARY 2
REDUNDANT 2
STATUS
CONFIG
AACC
Figure 6. Front Panel Configuration Port, FOX Matrix 320x
FOX MATRIX 14400
CONFIG
FIBER OPTIC DIGITAL MATRIX SWITCHER
POWER SUPPLY
PRIMARY
REDUNDANT
BBCC
Figure 7. Front Panel Configuration Port, FOX Matrix 14400
A
Configuration port (FOX Matrix 320x) — If desired, connect control
system or computer to the front panel Configuration (USB) port. Use
a standard mini USB B cable.
B
Configuration port (FOX Matrix 14400) — If desired, connect a
control system or computer to the front panel Configuration (RS-232)
port. Use an optional 9-pin D to 2.5 mm mini jack TRS RS-232 cable.
C
Indicator LEDs
Primary and Redundant Power Supply LEDs
Green — Indicates that the associated power supply is operating
within normal tolerances.
Amber (FOX Matrix 320x only) — Indicates that AC power is
disconnected or the power supply has been removed.
Red — Indicates that the associated power supply is operating
outside the normal tolerances or has failed see Removing and
Installing a Power Supply Module on page 25) to replace the
power supply.
Status LED (FOX Matrix 320x only) —
Green — Indicates that the controller board is operating normally
and that the temperature and backplane voltages are all within
normal tolerances.
Red — Indicates that either the controller board has failed or that
temperature or backplane voltages are outside of acceptable
levels.
Page view 8