5-3
VoiceLift
Microphone • Installing and Mounting the Receiver
PRELIMINARY
Room factors to be considered should include, but are not confined to:
Room conguration
Line-of-sight obstructions between microphone and receiver
Ceiling and wall type (important in assessing the installation hardware
needed)
Location of the VLR 102 receiver
 Best location is on the ceiling, at the middle of the classroom.
If ceiling mounting is not possible, place high and centered on the longest
wall.
Student Desks
Teacher’s Desk
TV / VCR / DVD
Inputs
Screen/White
Board Location
MLC Controller
Location
PVT A/V Wallplate Location
Projector/
Switcher
Location
Speaker
Locations
Potential
VLR 102 IR
Receiver
Locations
Example of a classroom installation
Locations to avoid:
Places where line of sight could be obstructed; e.g., too close to the
projector
Corners of the room
On walls, at less than 6' or more than 12' up from the base
Areas that receive direct sunlight
Need for optional VLR 102 SR secondary receiver
One or more secondary receivers (VLR 102 SR) may be needed if:
The room is larger than 40' by 40'.
Obstructions exist between the microphone and the receiver.
The room is odd-shaped, e.g., L-shaped or long.
The room has recessed or sheltered areas, such as alcoves or bays.
The room has large windows or windows on multiple walls.
Portions of the walls are dark and/or covered. Dark surfaces reduce
signal reection.