Configuration
This section of the user guide provides information about:
RS-232 Ports
RS-232 Control of Tx and Rx Units
SIS Commands
Control Program
RS-232 Ports
Both the FOX Tx AV and FOX Rx AV have a front panel TRS port and a rear panel captive
screw port, which can provide SIS commands to configure the transmitter/receiver settings
when connected to a control device.
SIS commands for the FOX Tx/Rx AV start on page 13.
NOTE: The two comm ports work in parallel. However, depending on the computer or
the communication settings, connecting to both comm ports at once may result
in one or both ports not working. Extron recommends that only one comm port
(front or back) is used at a time.
The protocol for both ports is 9600 baud, no parity, 8 data bits, 1 stop bit, and no flow
control.
NOTE: Both RS-232 Remote and RS-232 Over Fiber signals require fiber optic link 1 and
link 2 for full functionality (see page 12).
The front panel Config port uses a 2.5 mm mini jack connector. Extron recommends the
9-pin D Female to 2.5 mm TRS Configuration Cable (part number 70-335-01)
Sleeve (Gnd)
Ring
Tip
2.5 mm TRS connector
Pin TRS
Tip
Ring
Sleeve
Function
Transmit data
Receive data
Signal ground
T
x
R
x
Figure 7. Front Panel RS-232 Port