68-1692-01 Rev. B08 10TouchLink 3.5” Cable Cubby TouchpanelTLP 350CVInstallation Guide®™Architectural ConnectivityCoverContentsCover iPrecautions i
RequirementsHardware and SoftwareThe following system requirements are recommended for running GUI Configurator or Global Configurator 3: z Operating Sy
Preparing the Table This section includes the following topics: z Installation Overview z Cutout DimensionsTLP 350CV • Prepare the Table 5Installation
TLP 350CV • Prepare the Table 6Cutout DimensionsCutout dimensions are available from Extron as a router guide, printed dimensions for a CNC wood rout
Mounting the Enclosure This section includes the following topics: z Installing the Power Module, Cables and AAPs z Mounting the Enclosure Installing
Install the Power Module and Shelf AssembliesNOTE: The included power module takes up two (US) or three (Int’l) AAP spaces and must be installed on t
Mounting the EnclosureCAUTION: The trim ring edges can easily be nicked or bent. Exercise caution when handling and mounting the enclosure. 1. Remov
Connecting the Touch Panel This section includes the following topics: z Connecting the TLP 350CV z Mounting the Power Supply (US models only)Connecti
CAUTION: Always use a power supply supplied or specified by Extron for use with the TLP 350CV. Use of an unauthorized power supply voids all regulator
Initial ConfigurationThis section provides information on the front panel controls and indicators, the on-screen menus used to configure the TLP 350CV,
c Speaker — Provides audio feedback of button or panel presses.d Congurable Side buttons — 10 dedicated, customizable function buttons provide quic
This symbol is intended to alert the user of important operating and mainte-nance (servicing) instructions in the literature provided with the equipme
MainVolTimeIP ExitDn UpDnOnOnUpOnSleep timer: 50000 SecBacklight: 073%AutoVidMotionLEDBacklightMain MenuProvides adjustment of the sleep timer and t
Volume ControlThe Volume Control menu allows the user to adjust the maximum volume of the sound, individual volume of button click feedback, and audio
Main192.168.254.254MAC00-05-A6-05-7D-A6Off255.255.000.000IP AddressDHCPSubnet MaskIP (Network)The IP configuration menu displays network-related parame
++ ++Press and HoldHighlighted BoxUntil Color ChangesVideo The video menu adjusts the appearance of a video signal connected to the video inputs. Use
Configuration SoftwareThe section provides information on the following topics: z Conguration and Control Software z Installing Software z Using the T
If required, locate the Global Configurator program on the disc or Web site and install that also. By default, the Installer program creates and places
Figure 8. System Settings3. Selecting Passwords allows the user to set passwords for an Administrator and a User. To set a password, follow the inst
Figure 10. Touchpanel Conguration TLP 350CV • Conguration Software 21
Using GUI ConfiguratorThis section provides an overview of the GUI Configurator program. For complete information about the program, consult the GUI Con
Figure 12. GUI Congurator Start Options Dialog Box2. You can choose to: z Start a New Project — Clicking OK opens a dialog box that offers a choice
FCC Class A NoticeThis equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rule
z Open an Existing Project — Clicking OK opens a dialog box that allows you to navigate to an existing project for modification.Figure 14. GUI Congu
3. Depending on which option was selected in step 2, GUI Configurator opens to a new or an existing project. The initial screen is divided into a seri
b. The Panel Manager dialog box opens:Figure 18. Add a TouchLink panel (5b)c. Click on the Add Panel Icon to add a new panel to the list in the lef
Using Global ConfiguratorNOTE: To configure the TLP 350CV, use Global Configurator version 3.0.4 or later.This section provides an overview of the Globa
Figure 20. Global Congurator Project Settings3. Enter the IP Address for the TLP 350CV panel.The default Telnet connection is port 23 and HTTP is p
4. Click OK and the Project Settings screen closes and is replaced by the “Add Device” dialog box:Figure 21. Global Congurator Add Device Dialog Bo
5. Click OK and the Add Device screen closes. The start-up screen, which was behind it, is now visible, showing the IPL 250 and the available ports:F
7. The “Add TouchPanel” dialog box opens.Figure 24. Add Touchpanel Dialog Boxa. Ensure the TouchLink panel model is selected from the drop-down men
Reference Information z Specications z Product Dimensions z Part Numbers (Included parts) z Accessories (Optional)Specifications DisplayScreen type ..
Control— touch panelLid switch ... On/offLight sensor ... On/offExternal butto
FRONT VIEWTLP 350CVBOTTOM VIEWTOP VIEWRIGHT SIDE VIEWLEFT SIDE VIEWNOTE: Architectural Adapter Plates (AAPs) shown in the diagrams above and in photo
Regulatory complianceSafety ... CE, c-UL, ULEMI/EMC ... CE, C-tick, FCC Class A,
Part Numbers (Included parts)Description Part numberTLP 350CV (US black anodized) TLP 350CV (US brushed aluminum) TLP 350CV (EU black anodized) TLP 35
Accessories (Optional)Description Part numberTLP 350CV routing template 70-694-01Individual Buttons (see www.extron.com)German/French Button Kit 70-69
Reset Modes, Button Replacement, Firmware Updates z Reset Modes z Button Kits z Button Replacement z Updating FirmwareLEDResetMenu Figure 26. Reset B
TLP 350CV Reset Mode SummaryMode Mode Activation Result Purpose/NotesUse Factory Firmware1Hold the reset button while applying power.NOTE: After a mod
Button KitsAll ten positions of front panel buttons may be replaced with buttons used to customize the appearance and functionality of the TLP 350CV T
Updating FirmwareFirmware for the TLP 350CV can be upgraded using the Extron Firmware Loader, a web browser and the default web pages, or GUI Configura
Updating Firmware with Firmware Loader1. Power on a computer with internet access and ensure the computer and the TLP 350CV are connected to the same
7. Click File | Open and navigate to the folder where the firmware file is located. Click on the file to select it, then click Begin. 192.168.254.254 V0
TLP 350CV • Contents vContentsIntroduction ... 1About This Guide ...
Updating Firmware From a Web Browser1. Power on a computer with internet access.2. Ensure the computer and the TLP 350CV are connected to the same n
Extron® WarrantyExtron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of pur
TLP 350CV • Contents vi
TLP 350CV • Introduction 1Introduction z About This Guide z About the TLP 350CV z Features z RequirementsAbout This GuideThis guide describes the fun
TLP 350CV • Introduction 2FeaturesTLP 350CV features include: 3.5 inch LCD screen — displays a wide range of customizable graphics.Touch screen overl
TLP 350CV • Introduction 3ExtronRGB 580xiInterface ExtronIPL 250IP Link EthernetControl ProcessorSOGSERRDDSPV-SYNC WIDTHNEG SYNCCOMP SYNCINPUTSRGB 58