Command and Response Table for SIS Commands (continued)
DMS 1600, DMS 2000, DMS 3200, and DMS 3600 • Programming Guide 57
Command ASCII Command
(Host to Unit)
Response
(Unit to Host)
Additional Description
Information requests (continued)
Request system status
S
DMS 1600 response
X1*
X1*
X1*
X1*
X1*
X1*
X1*
X1(
X2)
X2)
X2!
X2!]
DMS 2000 response
X1*
X1*
X1*
X1*
X1*
00
.
00
00
.
00
X1(
X2)
00000
X2!
0
]
DMS 3200 response
X1*
X1*
X1*
X1*
X1*
00
.
00
00
.
00
X1(
X2)
X2)
X2!
0
]
DMS 3600 response
X1*
X1*
X1*
X1*
X1*
X1*
X1*
X1(
X2)
X2)
X2)
X2)
X2!
X2!]
Response description (DMS 1600):
+3.3V•+5V•+1.3V•+1.2V•+12V (system volts)•+12V (redundant PS)•+12V (Primary PS)•Temp•Fan 1 RPM•Fan 2 RPM•Pri PS•Red PS
]
Response description (DMS 2000):
+3.3V•+5V•+1.3V•+1.2V•+12V (system volts)•
00
.
00
00
.
00
•Temp•Fan RPM•
00000
•PS•
0
]
Response description (DMS 3200):
+3.3V•+5V•+1.3V•+1.2V•+12V (system volts)•
00
.
00
00
.
00
•Temp•Fan 1 RPM•Fan 2 RPM•PS•
0
]
Response description (DMS 3600):
+3.3V•+5V•+1.3V•+1.2V•+12V (system volts)•+12V (redundant PS)•+12V (Primary PS)•Temp•Fan 1 RPM•Fan 2 RPM•Fan 3 RPM•Fan 4 RPM•
Pri PS•Red PS
]
NOTE: The response to the View File Directory command differs, depending on whether the command is sent via an RS-232/RS-422 or
Telnet connection or via a web browser connection.
View file directory
RS-232/RS-422 port and
Telnet
E
DF
}
filename1,date/time,length
]
List user-supplied files.
filename2,date/time,length
]
filename3,date/time,length
]
• •
• •
filenamen,date/time,length
]
# of Bytes•Left
]]
View file directory
web browser
E
DF
}
Var file = new array (); List user-supplied files.
File [1] = ‘filename1,date1,filesize1’;
File [2] = ‘filename2,date2,filesize2’;
File [3] = ‘filename3,date3,filesize3’;
• •
• •
File [n] = ‘filenamen,daten,filesizen’;
File [n+1] = # of Bytes•Left
Erase a user-supplied web
page or file
E
filenameEF
}
Delfilename
]
NOTE: X1* = Voltage (positive or negative voltage and magnitude)
X1( = Temperature Degrees Fahrenheit
X2) = Fan speed In revolutions per minute (RPM)
X2! = Power supply status 0 = not installed or failed 1 = installed and OK