3. If you selected IP [LAN] in step 2, the IP Connection dialog box opens (see figure 35).
Figure 35. Address and Password Entry
a. Examine the Matrix IP Address field in the IP Connection dialog box.
The field displays the last Extron IP address entered.
If the IP address is correct, proceed to step 3b.
If the address is not correct, either click in the Extron IP Address field and
enter the IP address or click the scroll down button ( ) and select from among
the recently used addresses. Proceed to step 3b.
NOTE: If the local system administrators have not changed the value, the
factory-specified default, 192.168.254.254, is the correct value for this
field.
b. If the switcher is password protected, click in the Password field and enter the
appropriate administrator or user password.
c. Click Connect.
If you logged on with the administrator password, the program connects you to the
matrix switcher with all of the administrator rights and privileges. The Extron Matrix
Switchers Control Program window (see figure 36 and figure 37 on the next page)
opens, displaying the current configuration of the attached matrix. Proceed to
“Using the program,” below.
If you logged on with the user password, the program connects you to the matrix
switcher with only user capabilities.
If an incorrect password was entered, the computer beeps and the program returns
to the password entry display.
Using the program
To create a tie, click and drag an input box to one or more output boxes. To remove a
tie, drag the output box to its tied input box or to the trash can.
To make the control program easier to use, assign a device icon to each input and
output. Click on a box that represents an input or output, and drag the desired icon
onto the box from the icon palette that opens.
For quick display of information on a specific input or output device, position the pointer
tool over that device in the control program window. The program opens a pop-up that
details the connections to that device and the signal status (present or missing) input
from or output to that device (see the inset box in figure 37 on the next page).
TIP: You can print a map of the current configuration by clicking File > Print