Serial Port Login Procedure
1. From the Login: prompt, type config followed by the <Enter> key.
2. When prompted for a password, type config followed by the <Enter> key.
The following menu will then appear.
Network Port 1 Network Port 2
============== ==============
0. Speed/Duplex: auto_10_100_1000 10. Speed/Duplex: auto_10_100_1000
1. Boot method: static [dhcp] 11. Boot method: static [dhcp]
2. address: 192.168.0.1 12. address: 192.168.1.1
3. netmask: 255.255.255.0 13. netmask: 255.255.255.0
4. gateway: 192.168.0.1 14
Gateway: 192.168.0.1
5. broadcast: 15. broadcast:
6. mtu: 1500 16. mtu: 1500
7. controller ip: 192.168.0.18 17. ip forwarding: 0
8. controller port: 5432 18. webserver port: 80
9. Exit
3. Type the menu option number required followed by the <Enter> key.
4. Where required, type the new value followed by the <Enter> key.
5. To exit the menu and return to the main command prompt, type 9 followed by the
<Enter> key.
Command options
The following commands are also supported from the main command prompt:
Exit To logout from the session
Reboot To force the VN 200 device to restart
Ping To test network communications with another device (see
Understanding Network Performance”)