Extron-electronics ISM 482 User Manual Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 82
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
ISM 482 Integrated Scaling Matrix Switcher • Installation 10
Wiring the network cable
The cable can be terminated as either a patch cable or a crossover cable (see figure 9) and
must be properly terminated for your application:
• Patch (straight) cable — Connection of the ISM to an Ethernet hub, router, or
switcher that also hosts a controlling computer
• Crossover cable — Direct connection between the ISM and a controlling computer
A cable that is wired as T568A at one end
and T568B at the other (Tx and Rx pairs
reversed) is a "crossover" cable.
A cable that is wired the same at both ends is
called a "straight-through" cable, because
no pin/pair assignments are swapped.
12345678
RJ-45
Connector
Insert Twisted
Pair Wires
Pins:
Crossover Cable Straight-through Cable
Pin
1
2
3
4
5
6
7
8
Wire color
White-green
Green
White-orange
Blue
White-blue
Orange
White-brown
Brown
Wire color
T568A T568B
End 1 End 2 End 1 End 2
White-orange
Orange
White-green
Blue
White-blue
Green
White-brown
Brown
Pin
1
2
3
4
5
6
7
8
Wire color
White-orange
White-green
Blue
White-blue
White-brown
Brown
Wire color
T568BT568B
White-orange
OrangeOrange
White-green
Blue
White-blue
GreenGreen
White-brown
Brown
Figure 9. RJ-45 Connector Pinout Tables
RS-232 Connection
h Remote port — Connect a host device, such as a computer or touch panel control,
to the integration scaling matrix switcher via this 9-pin D connector for serial RS-232
control (see figure 10).
RS-232 FunctionPin
1
2
3
4
5
6
7
8
9
TX
RX
Gnd
Not used
Transmit data
Receive data
Not used
Signal ground
Not used
Not used
Not used
Not used
51
9
5
9
6
Female
Male
1
6
Figure 10. Remote Port Pin Assignments
See Programming Guide on page 31, for definitions of the SIS commands and
Switcher Software on page 47, to install and use the control software.
Configuration
The ISM can be configured using either the front panel controls, the SIS, or the Windows
Control program (see the Operation section on page 16, the Programming Guide section
on page 38, the Switcher Software section on page 49, and the HTML Operation
section on page 60
Page view 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 81 82