MSG Matrix Switchers • Remote Control
5-3
Termination resistors should only be turned on when operating in RS-422/
RS-485 mode, and then only for the first and last units on a long serial line.
The default switch settings are all OFF. In half-duplex mode, only turn on one
of the termination resistors, as they are connected together by the cable.
Host-to-MSG Matrix Switcher Communications
All serial commands are applicable to both the MSG0804 and MSG0808,
except where the number of outputs differs between the two switchers. The
MSG Matrix Switchers accept serial control protocol commands through the
RS-232/RS-422/RS-485 port. These commands consist of one or more
characters per command field. They require a beginning delimiter ([) and an
ending delimiter (]).
Addressing commands
In RS-232 mode, there is no need to assign an address to the switcher,
however, if you are using RS-422 or RS-485 mode with several devices
connected in parallel to a single serial port, you will need to assign an
address for each unit.
The factory default for the MSG Matrix Switchers is no address. You must
assign an address between 01 and 98. In addition, 00 is a broadcast address,
and all connected units will perform the action commanded (no responses
will be sent).
Using the command table
The command table is shown on the following pages. Lower case characters
are acceptable in the command field only where indicated. Command and
response examples are shown throughout the command table.